HPLC with refractive index detection for sweeteners
Polyols, rare sugars and many fibre hydrolysates have no useful UV chromophore. HPLC-RI uses a refractive index detector, which responds to the difference in refractive index between the column eluent and the sample. It is the standard assay for erythritol, xylitol, sorbitol, allulose and the sugar profile of a fibre.
In short
A separation method for sugars and polyols that do not absorb UV light, reported against a standard.
The method
The separation usually runs on an amino or calcium-loaded ion-exchange column with water or a dilute acid mobile phase at an elevated temperature. The refractive index detector is temperature-sensitive, so the cell and the column are held at controlled temperatures. The sample is filtered and injected, and the peak areas are compared with standards of the named sugar or polyol.
The method must separate the target from its isomers. Erythritol, xylitol, sorbitol and mannitol can appear close together; allulose, fructose and glucose can overlap on a poorly optimised system. A certificate that reports a single peak without showing the separation is weaker evidence than one that shows the other polyols or sugars.
What the result proves
The result proves the amount of the named sugar or polyol and the presence of the other components the method resolves. For a polyol grade, the other-polyol figure is often the difference between a clean crystal and a blended powder. For a fibre, the sugar profile shows how much of the material is free glucose, fructose or sucrose.
RI detection is less sensitive than UV or mass detection, so trace impurities at parts per million are not its job. The method is for percent-level composition. Trace contaminants belong to ICP-MS, GC or a dedicated impurity method.
What it proves
- The assay of the named polyol or sugar against a standard.
- The other-polyol or other-sugar profile that the method resolves.
- The sugar composition of a fibre hydrolysate.
What it does not prove
- Trace contaminants at milligram or microgram levels.
- The botanical or enzymatic source.
- The crystal form and the particle size.
- The taste and the mouthfeel.
What to ask the laboratory
- Which column and mobile phase were used?
- How are the isomers separated and integrated?
- Does the method report the other polyols or sugars?
- What is the limit of detection for the minor peaks?
Read the assay together with the other-polyol or sugar profile and the moisture. A 99% erythritol with 3% maltitol is not the same grade as a 99% erythritol with 0.2% other polyols. The assay alone can hide the difference.
Where the method is used
- Erythritol — Erythritol, crystalline polyol.
- Xylitol — Xylitol, crystalline polyol.
- Allulose — D-Allulose, crystalline powder or liquid.
The method pages sit behind the COA page. The terms used here are defined in the buyer glossary, and the release limits are on the product specification.
Related documents
Send the certificate or specification you are reviewing and we will name the method behind each figure.
Request a specification review