Karl Fischer titration measures water directly. The sample is introduced into a reagent system in which water participates in a redox reaction, and the endpoint is detected electrochemically. The result is water content, not total volatile matter, which is why it is preferred for hydrates and for any grade where the moisture limit is tight.

In short

A water-specific titration that separates moisture from other volatile matter and reports water of crystallisation.

Why water-specific matters

Loss on drying captures water and any other volatile material under the test conditions. A powder with a residual solvent can show a high LOD and a normal KF result. For a hydrate, the water of crystallisation is part of the identity: trehalose dihydrate and sodium saccharin dihydrate both carry water in the crystal, and that water is not an impurity.

The sample preparation and the titration parameters are part of the method. A hygroscopic powder must be handled in a dry environment, and the sample size must be large enough to give a reliable endpoint without overloading the reagent.

What the result proves

The result proves the water content of the sample at the time of analysis. It supports the assay basis, the usable solids and the storage assessment. It does not prove the crystal form by itself; a dihydrate and a mixture of anhydrous material plus free water can return the same total water.

That distinction matters for trehalose. A KF result of 10% is consistent with the dihydrate, but the identity of the crystal should be confirmed by another method. For a polyol, a KF result above the specification is a reason to review the drying step and the pack.

What it proves

  • Water content, including water of crystallisation, by a water-specific method.
  • The moisture basis for the assay and the usable solids.
  • Whether a lot is inside the specification for a hydrate or a low-moisture grade.

What it does not prove

  • The crystal form when free water and water of crystallisation are both present.
  • Residual solvents, which are a separate test.
  • The microbiological quality of the lot.

What to ask the laboratory

  1. Was the moisture measured by KF or LOD?
  2. What is the sample size and the reagent system?
  3. Is the water of crystallisation included in the specification?

Read KF with the specification's moisture limit and the form. A dihydrate should carry its water; an anhydrous grade should not. A result outside the limit is a drying or a pack issue until proven otherwise.

Where the method is used

The method pages sit behind the COA page. The terms used here are defined in the buyer glossary, and the release limits are on the product specification.

Send the certificate or specification you are reviewing and we will name the method behind each figure.

Request a specification review

Next step

A number without a method is not a result.

Send the certificate and we will name the method, the limit and the gap.