M Contaminants · ICP-MS

ICP-MS elemental analysis for sweeteners

Technical note · Reviewed 18 November 2026 · All methods

ICP-MS ionises the sample in an argon plasma and measures the ions by mass. It is the standard method for the heavy-metal panel on a food ingredient: lead, arsenic, cadmium and mercury, usually with additional elements where the specification or the market requires them.

In short

A multi-element method that measures lead, arsenic, cadmium, mercury and other trace elements at microgram-per-kilogram levels.

The method

The sample is digested, usually with nitric acid and heat or microwave assistance, to bring the metals into solution. The digest is nebulised into the plasma, and the mass spectrometer counts the ions at the selected mass-to-charge ratios. Internal standards correct for drift and matrix effects, and certified reference materials check the calibration.

The detection limits are far below the specification limits, which is what makes the method useful. A result of 0.02 mg/kg lead is meaningful only when the laboratory can state the limit of quantification and the digestion blank. A certificate that reports 'not detected' without a limit is not telling the buyer what was measured.

What the result proves

The result proves the concentration of the measured elements in the sample that was digested. It does not prove that the sample is representative of the whole drum, which is why the sampling plan matters. It does not cover organic contaminants, pesticides, residual solvents or microbiology.

For a sweetener, the heavy-metal panel is a release test. The limits depend on the destination market and the food category. A lot inside the specification is not automatically compliant with every market's rules; the specification should be set against the strictest market the product is sold into.

What it proves

  • Lead, arsenic, cadmium and mercury at the stated limits of quantification.
  • Additional elements requested in the specification.
  • Whether a lot meets the agreed contaminant limits.

What it does not prove

  • Pesticides, mycotoxins and residual solvents.
  • Microbiological quality.
  • Whether the sample represents the whole lot.

What to ask the laboratory

  1. What is the limit of quantification for each element?
  2. Which digestion and internal standards were used?
  3. Is the laboratory accredited for this method?
  4. Was the sample drawn from the lot or from a sample cabinet?

Read the result with the limit of quantification and the specification limit. Compare the limit of quantification with the specification limit; a method that cannot measure below that limit is not fit for the release decision.

Where the method is used

The method pages sit behind the COA page. The terms used here are defined in the buyer glossary, and the release limits are on the product specification.

Send the certificate or specification you are reviewing and we will name the method behind each figure.

Request a specification review

Next step

A number without a method is not a result.

Send the certificate and we will name the method, the limit and the gap.